KNOW
AVAILABLE
1GSa/s Real-Time Sampling, 100MHz
4-Channel Digital Storage Oscilloscope
with VGA (640x480)
COLOR Display
Stand
alone oscilloscope features: |
 |
- 1GSa/s,
100MHz Analog Bandwidth
- Pre/Post
Trigger selectable
- Various
intern/extern triggering
- Trigger
Hold Off
- Pulse
Width Trigger Selections
- Large
6.5" VGA (640x480dots) Color TFT LCD
- 16KB
Memory Depth per Channel
- XY-Mode
- Automatic
Measurements
- Autoscale
- Minor
Mathematic Functions, no FFT
- No Timebase
Delay Function
- Easy
to use due to soft key design
-
Free PC Software Application available (see demo
download)
- Four
Signal Probes included
- 3 years
warranty
- EUR
1495 + Tax +S/H
- Data
Sheet & Pricing W2000ADSeu.pdf
(Stand 12 June 2008)
| LCD |
6.5", 640
x 480 dots TFT VGA Color |
| Serial Interface |
USB (included) |
| Serial Cable |
6 ft (included) |
| Keyboard |
silicone keys
and rotary switches |
| Power
Supply |
internal, 90VAC to 250VAC |
| Channel |
4 identical
channels
plus external trigger |
| Timebase |
50ns/div to 5sec/div |
Signal
Refresh Rate
|
at timebase setting to 50ns/div:
Single Channel Operation
approx. 10 recordings/sec
Dual Channel Operation
approx. 5 recordings/sec
Three Channel Operation
approx. 3 recordings/sec
Four Channel Operation
approx. 2 recordings/sec |
| Analog Bandwidth
|
10Hz - 100MHz |
| Coupling |
AC/DC/Ground
on all channels |
| Input Impedance |
Probe set to
1:1, 1MOhm/60pF
Probe set to 1:10, 10MOhm/30pF |
| Sensitivity |
0.25mV/dot to
125mV/dot (LCD resolution)
10mV/div to 5V/div,
selectable in [1,2,5] steps |
| Max. Input Voltage |
Without Probe
max. 30Vpp
With Probe max. 300Vpp
|
Max. vertical move
|
±5 divisions |
| Scope Modes |
Normal and Single
Shot |
| Normal |
50ns/div (1GSa/s)
to 5sec/div |
| Single shot |
50ns/div (1GSa/s)
to 5sec/div |
| Time Base Accuracy |
±0.5%
at 5V/div, 500mV/div, 50mV/div
(no noise, perfect performance)
±5% at 2V/div, 1V/div, 200mV/div
100mV/div (some low noise)
±10% at 10mV/div and 20mV/div
(some noise)
|
| Trigger |
AUTO or On Trigger
intern or external (+/- Normal)
When AUTO, min. 10 periods needed to
trigger stable. Otherwise set to NORMAL. |
| Trigger Source |
Channel on any
channel
negative or positive transition |
| Pre/Post Trigger |
Anywhere within
the Memory Depth |
| Memory
Depth |
16k points/channel 50ns/div - 500ns/div
4k points/channel 10µs/div - 200ms/div |
| Automatic Measurements |
16, (reduces
refresh rate respectively) |
| Firmware |
vertical/horizontal cursors all parameter selectable
via PC attached, Numerical Measurement, trigger/zero
level, cursors, cursors, grid, store recorded data,
Auto-Scale |
| PC Software |
for Windows (free download from our web site), No
FFT Analysis, No Math, Numeric Lists, Print/Save/Load
recorded data, and many more |
| Signal Probes |
1:1/10:1 selectable,
4ft, max. 600V |
| Dimensions Module |
330 x 166 x
92 mm |
| Opperation Environment |
Full accuracy
from 0 to 40°C and 80% RH (non-condensing) at
30°C |
| Storage Environment |
Storage Environment
0° to 40°C |
| Certifications |
CE,
EN 61326-1:2006-05,
EN 61326-2-1:2006,
EN 61000-4-2:1995 + A1:1998 + A2:2001
EN 61000-4-3:2006-12
EN 61000-4-4:2004
EN 61000-4-5:1995 + A1:2001
EN 61000-4-6:1996 + A1:2001
EN 61000-4-11:1994-08 + A1:2001-02 |
| Country
of Origin |
Custom manufactured in the
United Kingdom, Europe |
|
|
| |
|
|